Regular boiler
Checked against its sources: Updated
A regular boiler, also called a heat-only or conventional boiler, heats radiators and a hot water cylinder, usually with a cold water tank in the loft feeding the cylinder.1 Many run on an open-vented system, though not all.2
- Covers
- Heat-only boilers on gas, LPG or oil, UK homes.
- You
- Read any gauge, set controls and timer. On a sealed version, top up as your own user manual allows.
- A professional
- Everything inside the case, gas or oil supply, flue. Gas Safe registered engineer for gas; an OFTEC registered technician for oil.
1 What is in the set-up
Worcester Bosch describes three parts: the boiler, a cold water tank that feeds the hot water store, and a hot water tank that holds heated water in bulk1. Baxi adds that open vented systems usually have two loft tanks, a larger one feeding the cylinder and a smaller one keeping the heating system topped up and leaving room for expansion4.
Because the stored water and the cold tank do the work, Worcester Bosch says these systems can operate well even with low mains pressure, and that an existing older system can often be replaced using its pipework and radiators1. That is a maker's own description of its product, so an installer's survey of the actual house matters more.
2 Not every regular boiler is open vented
A regular boiler can still have a gauge to watch. The Baxi 600 Heat guide says a heat-only boiler may be on either an open-vented or a sealed system, and tells anyone unsure to ask their installer2. Worcester's 8000+ regular boiler manual makes the same split: open vented systems have pressure kept automatically by the header tank, while sealed ones are pre-pressurised and must be kept topped up5.
| Open vented | Sealed heat-only | |
|---|---|---|
| Water top-up | Automatic from the loft tank5 | Filling device, by hand5 |
| Gauge reading | Not used, on the oil guide read6 | Check against your manual, see boiler pressure |
| Loft tank for the heating | Yes4 | No4 |
On the Greenstar Heatslave oil range, Worcester treats the gauge as unused on open vent systems, with a word to the installer if it ever shows over 1 bar6. That is one model family's wording, and may not carry across.
3 Upkeep
A loft tank and cylinder add parts a combi does not have. Inspection and servicing fall to a qualified engineer; see boiler service. For the store itself, see hot water cylinder.
Sources
- What is a regular boiler, Worcester Bosch read 3 November 2026.
- Baxi 600 Heat user guide 7726861-01, p20, 1/19, read 3 November 2026.
- Vaillant on open vent boilers read 3 November 2026.
- Baxi's glossary read 3 November 2026.
- Worcester Greenstar 8000+ regular manual 6721890764, p6, 2024/06, read 3 November 2026.
- Worcester Greenstar Heatslave oil user guide 8716106253, p8, 03.2010, read 3 November 2026.